Reproducibilidad de la batería EPESE de desempeño físico en atención primaria

dc.contributor.authorCabrero García, Julio
dc.contributor.authorReig Ferrer, Abillo
dc.contributor.authorMuñoz Mendoza, Carmen
dc.contributor.authorCabañero Martínez, María José
dc.contributor.authorRamos Pichardo, Juan Diego
dc.contributor.authorRichart Martínez, Miguel
dc.contributor.authorGonzález Llopis, Lorena
dc.contributor.authorSanjuán Quiles, Ángela
dc.contributor.authorGómez Moreno, Nieves
dc.contributor.authorGarcía Beviá, Soledad
dc.date.accessioned2012-07-11T10:01:53Z
dc.date.available2012-07-11T10:01:53Z
dc.date.issued2007
dc.description.abstractObjetivo. Estimar la reproducibilidad de tres medidas objetivas de desempeño f{sico de personas mayores en atención primaria. Diseño. Estudio descriptivo y prospectivo con observación directa de la función f{sica por parte de profesionales de la salud de acuerdo a un protocolo estandarizado. Emplazamiento. Tres centros de atención primaria de las provincias de Alicante y Valencia. Participantes. Muestra de 66 personas de 70 y más años, evaluadas en dos ocasiones por el mismo profesional al objeto de replicar idénticas condiciones del estudio, en un intervalo temporal de dos semanas (mediana de 14 días). Mediciones principales. Se evaluó el funcionamiento físico a través de tres pruebas objetivas de desempeño: el test de equilibrio, el de velocidad de la marcha. y la capacidad para levantarse y sentarse de una silla. Estas medidas provienen de los estudios EPESE (Established Populations forEpidemiologic Studies of the Elderly). Se ha calculado la fiabilidad test-retest mediante el coeficiente de correlación Intraclase. Resultados. Los coeficientes de correlación intraclase (CCI) fueron de 0,55 para el test de equilibrio, de 0,69 para el test de levantarse de la silla, y de 0,79 para el de velocidad de la marcha. El valor para la puntuación total de la batería EPESE fue de 0,80. Conclusiones. La reproducibilidad de estas medidas de desempeño es tan aceptable como las aportadas por la bibliografía de referencia. Estas pruebas de desempeño permiten evaluar con rigor cambios importantes en funcionamiento y salud que se producen con el tiempo.en_US
dc.description.abstractObjective. To estimate the reproducibility of three direct measures of physical performance from the Short Physical Performance Battery, or EPESE Battery, in primary ca re. Design. Prospective and descriptive study based on direct observation of physical function by health professionals using a standardised method. Setting. Three primary care health centres in the provinces of Alicante and Valencia, Spain. Participants. A sample of 66 subjects, 70 or more years, was selected. Subjects were tested in Primary Care contexts twice (time interval of 2 weeks, median 14 days) by the same interviewer to replica te study conditions. 69 Main measurements. Performance-based functional status was evaluated by three performance tests: standing balance, gait speed, and chair stand. These tests were adapted from the EPESE studies (Established Populations for Epidemiologic Studies ofthe Elderly). Intra-class correlation coefficients (ICCs) were used to assess direct measures of performance. Results. Intra-class correlations coefficients were 0.55 for standing balance, 0.69 for chair stands, and 0.79 for gait speed. An ICC of 0.80 for global EPESE battery was obtained. Pearson correlations values are of similar magnitude to the ICCs values. Conclusion. Several commonly used measures of performance may be reliable as originally reported. Performance measures may be valuable for assessing major changes in health and functioning over time.eng
dc.identifier.urihttp://hdl.handle.net/10272/5813
dc.language.isospaen_US
dc.publisherUniversidad de Huelvaen_US
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subject.otherFiabilidad test-retestspa
dc.subject.otherEvaluación del desempeño físicospa
dc.subject.otherBatería EPESEspa
dc.subject.otherAtención primariaspa
dc.subject.otherTest-retest reliabilityeng
dc.subject.otherPhysical performance assessmentseng
dc.subject.otherEPESE batteryeng
dc.subject.otherPrimary careeng
dc.titleReproducibilidad de la batería EPESE de desempeño físico en atención primariaen_US
dc.typejournal articleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication506bd5c4-c746-4240-b834-f64fe1efa0ab
relation.isAuthorOfPublication.latestForDiscovery506bd5c4-c746-4240-b834-f64fe1efa0ab

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Reproducibilidad_de_la_bateria_epese.pdf
Size:
985.4 KB
Format:
Adobe Portable Document Format