RT Journal Article T1 Effect of low intensity static magnetic field on purified water in stationary condition: ultraviolet absorbance & contact angle experimental studies A1 Dueñas Díaz, José Antonio A1 Weiland Ardaiz, Carlos María A1 Núñez, Miguel Ángel A1 Ruiz Rodríguez, Francisco Javier AB This work focused its attention on the effect of low intensity static magnetic field on purified water: more specifically, on how the ultraviolet absorbance and the surface tension of the water may be affected. It has been found that pure water, exposed to a magnetic field for periods of time, does not absorb the ultraviolet radiation in an asymptotic way, but shows a local maximum at 15 minutes. It is also shown that the contact angle of droplets on paraffin can be reduced by up to 5 degrees by exposing the water to a 10 mT static magnetic field. PB American Institute of Physics SN 0021-8979 SN 1089-7550 (electrónico) YR 2020 FD 2020-04-07 LK https://hdl.handle.net/10272/24179 UL https://hdl.handle.net/10272/24179 LA eng NO J.A. Dueñas, C. Weiland, M.A. Núñez, and F.J. Ruiz-Rodriguez. Effect of low intensity static magnetic field on purified water in stationary condition: ultraviolet absorbance & contact angle experimental studies. Volume 127, Issue 13, DOI10.1063/1.5132420 (2020) DS Repositorio Institucional de la Universidad de Huelva RD 30 may 2026