@article{10272/22174, year = {2022}, url = {https://hdl.handle.net/10272/22174}, abstract = {We present the design, prototype developments and test results of the new time-of-flight detector (ToFD) which is part of the R3 B experimental setup at GSI and FAIR, Darmstadt, Germany. The ToFD detector is able to detect heavy-ion residues of all charges at relativistic energies with a relative energy precision σΔE/ΔE of up to 1% and a time precision of up to 14 ps (sigma). Together with an elaborate particle-tracking system, the full identification of relativistic ions from hydrogen up to uranium in mass and nuclear charge is possible.}, publisher = {Springer}, title = {A new Time-of-flight detector for the R3 B setup}, doi = {10.1140/epja/s10050-022-00875-8}, author = {Heil, M. and Sánchez Benítez, Ángel Miguel and Zanetti, Lorenzo}, }