Preanalytical errors in emergency department samples: Investigating error sources

dc.contributor.authorRomero Ruiz, Adolfo
dc.contributor.authorGómez Salgado, Juan
dc.contributor.authorRomero Arana, Adolfo
dc.contributor.authorGómez Fernández, José Antonio
dc.date.accessioned2020-11-04T09:13:51Z
dc.date.available2020-11-04T09:13:51Z
dc.date.issued2020
dc.description.abstractBackground: The presence of preanalytical errors is a recurring fact in all areas of healthcare that send samples to laboratories. Increasing the knowledge of possible sources of error in the preanalytical phase has been the objective of this group during the last 10 years. Methods: In this study, descriptive research has been carried out using professionals’ opinions obtained by means of the Strengths, Weaknesses, Opportunities, and Threats method in a focus group. Results: The opinions expressed within the focus group have emphasised the importance of patients’ safety and willingness for the introduction of a computerized analytical module. The most commented weakness in both hospitals was the transport of samples through the pneumatic tube. Improving the duration of workers’ contracts, especially in the laboratory, and creating a circuit for professional’s localization during the work shift to facilitate potential error solving are some opportunities for the future. Conclusions: Different approaches have been developed depending on the healthcare scenario. For this, establishing a flow of information between the different professionals allows identifying identical aspects through a priori, different points of view. The line to follow is to improve the safety of the patient and also to give professionals an opportunity to express themselves.es_ES
dc.description.departmentSociología, Trabajo Social y Salud Pública
dc.identifier.citationRomero, A., Gómez Salgado, J., Romero Arana, A. ... Gómez Fernández, J. (2020). Preanalytical errors in emergency department samples: Investigating error sources. Journal of Medical Biochemistry, 39(4), 474–480. DOI: https://doi.org/10.5937/jomb0-25263es_ES
dc.identifier.doi10.5937/jomb0-25263
dc.identifier.issn1452-8266
dc.identifier.urihttp://hdl.handle.net/10272/18988
dc.language.isoenges_ES
dc.publisherSOC MEDICAL BIOCHEMISTS SERBIAes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subject.otherEmergency hospital servicees_ES
dc.subject.otherHospital laboratoryes_ES
dc.subject.otherPreanalytical phase errorses_ES
dc.subject.otherQualitative researches_ES
dc.titlePreanalytical errors in emergency department samples: Investigating error sourceses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication93159467-aa6e-4dda-a463-d1a0bc4dee50
relation.isAuthorOfPublication.latestForDiscovery93159467-aa6e-4dda-a463-d1a0bc4dee50

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Preanalitycal.pdf
Size:
64.59 KB
Format:
Adobe Portable Document Format
Description:
Pdf versión editor

Collections