An upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectors
| dc.contributor.author | Barba Lobo, Alejandro | |
| dc.contributor.author | Mosqueda Peña, Fernando | |
| dc.contributor.author | Bolívar Raya, Juan Pedro | |
| dc.date.accessioned | 2022-01-12T10:45:51Z | |
| dc.date.available | 2022-01-12T10:45:51Z | |
| dc.date.issued | 2021-09-11 | |
| dc.description.abstract | The regulation existing on NORM activities requires the accurate and quick measurement of natural radionuclides in a wide range of matrices by gamma spectrometry. The aim of this work has been to develop a comprehensive and accurate methodology to determine natural long-lived radionuclides (210Pb, 228,226Ra, 234,228Th and 40K) by gamma spectrometry with Ge detectors in NORM samples. An exhaustive calibration method to obtain the full-energy peak efficiency (FEPE), for each gamma emission energy, as a function of the thickness, apparent density and matrix composition of the cylindrical sample, has been developed. The selected certified calibration standards contain only natural radionuclides belonging to the 238U- and 232Th-series as well as 40K (codes RGU-1, RGTh-1 and RGK-1 from IAEA). Then, the obtained FEPE curves were validated using Genie 2000 simulations and Certified Reference Materials, for which the self-attenuation corrections were considered. Finally, a study on 222Rn losses was done for several samples. | es_ES |
| dc.description.department | Ciencias Integradas | |
| dc.description.sponsorship | Funding for open access charge: Universidad de Huelva / CBUA | |
| dc.identifier.citation | Barba Lobo, A., Mosqueda, F., Bolívar, J.P.: "An upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectors". Measurement, Vol. 186, 110153, (2021). https://doi.org/10.1016/j.measurement.2021.110153 | es_ES |
| dc.identifier.doi | 10.1016/j.measurement.2021.110153 | |
| dc.identifier.issn | 0263-2241 | |
| dc.identifier.uri | http://hdl.handle.net/10272/20392 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier | |
| dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
| dc.rights.accessRights | open access | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
| dc.subject.other | Gamma spectrometry | |
| dc.subject.other | Ge detectors | |
| dc.subject.other | Efficiency calibration | |
| dc.subject.other | NORM | |
| dc.subject.other | Self-attenuation | |
| dc.subject.other | 222Rn losses | |
| dc.title | An upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectors | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | VoR | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 5befcd01-3cf2-4de2-907d-8fa8555f701b | |
| relation.isAuthorOfPublication | d4bcd1fb-24c3-4497-bac0-e1d5c86904f0 | |
| relation.isAuthorOfPublication.latestForDiscovery | 5befcd01-3cf2-4de2-907d-8fa8555f701b |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- A. Barba-Lobo_et_al_2021.pdf
- Size:
- 2.54 MB
- Format:
- Adobe Portable Document Format
- Description:
- Versión editor