An upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectors

dc.contributor.authorBarba Lobo, Alejandro
dc.contributor.authorMosqueda Peña, Fernando
dc.contributor.authorBolívar Raya, Juan Pedro
dc.date.accessioned2022-01-12T10:45:51Z
dc.date.available2022-01-12T10:45:51Z
dc.date.issued2021-09-11
dc.description.abstractThe regulation existing on NORM activities requires the accurate and quick measurement of natural radionuclides in a wide range of matrices by gamma spectrometry. The aim of this work has been to develop a comprehensive and accurate methodology to determine natural long-lived radionuclides (210Pb, 228,226Ra, 234,228Th and 40K) by gamma spectrometry with Ge detectors in NORM samples. An exhaustive calibration method to obtain the full-energy peak efficiency (FEPE), for each gamma emission energy, as a function of the thickness, apparent density and matrix composition of the cylindrical sample, has been developed. The selected certified calibration standards contain only natural radionuclides belonging to the 238U- and 232Th-series as well as 40K (codes RGU-1, RGTh-1 and RGK-1 from IAEA). Then, the obtained FEPE curves were validated using Genie 2000 simulations and Certified Reference Materials, for which the self-attenuation corrections were considered. Finally, a study on 222Rn losses was done for several samples.es_ES
dc.description.departmentCiencias Integradas
dc.description.sponsorshipFunding for open access charge: Universidad de Huelva / CBUA
dc.identifier.citationBarba Lobo, A., Mosqueda, F., Bolívar, J.P.: "An upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectors". Measurement, Vol. 186, 110153, (2021). https://doi.org/10.1016/j.measurement.2021.110153es_ES
dc.identifier.doi10.1016/j.measurement.2021.110153
dc.identifier.issn0263-2241
dc.identifier.urihttp://hdl.handle.net/10272/20392
dc.language.isoeng
dc.publisherElsevier
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subject.otherGamma spectrometry
dc.subject.otherGe detectors
dc.subject.otherEfficiency calibration
dc.subject.otherNORM
dc.subject.otherSelf-attenuation
dc.subject.other222Rn losses
dc.titleAn upgraded lab-based method to determine natural γ-ray emitters in NORM samples by using Ge detectorses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication5befcd01-3cf2-4de2-907d-8fa8555f701b
relation.isAuthorOfPublicationd4bcd1fb-24c3-4497-bac0-e1d5c86904f0
relation.isAuthorOfPublication.latestForDiscovery5befcd01-3cf2-4de2-907d-8fa8555f701b

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A. Barba-Lobo_et_al_2021.pdf
Size:
2.54 MB
Format:
Adobe Portable Document Format
Description:
Versión editor

Collections