Non-Linear and Unbalanced Three-Phase Load Static Compensation with Asymmetrical and Non Sinusoidal Supply

dc.contributor.authorSánchez Herrera, María Reyes
dc.contributor.authorSalmerón Revuelta, Patricio
dc.date.accessioned2018-07-18T11:03:51Z
dc.date.available2018-07-18T11:03:51Z
dc.date.issued2004
dc.description.abstractP-q theory has been widely used to control active power filters since its formulation in 1983. The compensation strategy used by the p-q theory users has not suffered modification; so it is used the constant power compensation strategy. In this way, the supply instantaneous power after compensation is constant. This kind of compensation strategy has obtained good results in the case of balanced and sinusoidal voltages, however it has not been appropriate in the case of unbalanced or non sinusoidal voltages. In this paper it has been researched about the modifications necessary, into the p-q theory frame, to get control strategies which allow to attack the unit power factor compensation or the balanced and sinusoidal currents compensation.es_ES
dc.description.departmentIngeniería Electrónica, de Sistemas Informáticos y Automática
dc.identifier.citationSánchez Herrera, M.R., Salmerón Revuelta, P.: "Non-Linear and Unbalanced Three-Phase Load Static Compensation with Asymmetrical and Non Sinusoidal Supply (XIV Reunión de Grupos de Investigación en Ingeniería Eléctrica) (Barcelona (Spain), 2004). DOI 10.24084/repqj02.263es_ES
dc.identifier.doi10.24084/repqj02.263
dc.identifier.urihttp://hdl.handle.net/10272/15100
dc.language.isoenges_ES
dc.publisherEuropean Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subject.otherInstantaneous reactive power.es_ES
dc.subject.otherPower quality.es_ES
dc.subject.otherThree-phase systems.es_ES
dc.subject.otherActive power filters.es_ES
dc.titleNon-Linear and Unbalanced Three-Phase Load Static Compensation with Asymmetrical and Non Sinusoidal Supplyes_ES
dc.typeconference outputes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationb62dcfe6-e843-4ed6-b672-071e1301977b
relation.isAuthorOfPublicationacbb1804-e3c7-463b-aeae-bc51215f04a2
relation.isAuthorOfPublication.latestForDiscoveryb62dcfe6-e843-4ed6-b672-071e1301977b

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Non-Linear and Unbalanced.pdf
Size:
568.48 KB
Format:
Adobe Portable Document Format
Description:
Versión editor
Loading...
Thumbnail Image
Name:
poster_non_linear.pdf
Size:
609.39 KB
Format:
Adobe Portable Document Format
Description:
póster