dc.description.abstractThe identification of distortion sources in a power system is a topic unsolved. The problem has a difficult solution because there are elements in the system that do not produce harmonic but amplifies the existing in the electrical network. The most common of those elements is the capacitor, very used to compensate power factor at fundamental frequency. The capacitor behaviour makes that the indices proposed up now to identify distorsion indices fail in the presence of this element. In this paper, a new one is presented: the load characterization index. Besides using an extended equivalent circuit to represent the load, this index calculates the distortion introduced by the load, evaluating, besides the current distortion at its input, the voltage distortion at its terminals. The introduction of voltage assesing makes the index suitable to identify the linear and nonlinear loads in the power system even in the presence of capacitors.es_ES
dc.description.departmentIngeniería Electrónica, de Sistemas Informáticos y Automática
dc.identifier.citationSánchez Herrera, M.R., Salmerón Revuelta, P., Pérez Litrán, S.: "Assessment of Harmonic Distortion Sources in Power Networks with Capacitor Banks". En: 11º International Conference on Renewable Energies and Power Quality - ICREPQ, (Las Palmas de Gran Canaria (Spain), 13th to 15th April, 2011)es_ES
dc.identifier.doi10.24084/repqj09.226
dc.identifier.urihttp://hdl.handle.net/10272/14935
dc.language.isoenges_ES
dc.publisherEuropean Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)es_ES
dc.relation.publisherversionhttps://doi.org/10.24084/repqj09.226es_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subject.otherPower Qualityes_ES
dc.subject.otherHarmonices_ES
dc.subject.otherDistortion Sourcees_ES
dc.subject.otherDistortion Assessmentes_ES
dc.subject.otherDistribution Networkses_ES
dc.subject.otherNon-Linear Loadses_ES
dc.titleAssessment of Harmonic Distortion Sources in Power Networks with Capacitor Bankses_ES
dc.typeconference outputes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationb62dcfe6-e843-4ed6-b672-071e1301977b
relation.isAuthorOfPublicationacbb1804-e3c7-463b-aeae-bc51215f04a2
relation.isAuthorOfPublicatione259a9da-11db-495d-8eb4-77d968be51ac
relation.isAuthorOfPublication.latestForDiscoveryb62dcfe6-e843-4ed6-b672-071e1301977b

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Assessment of Harmonic Distortion.pdf
Size:
167.34 KB
Format:
Adobe Portable Document Format
Description:
Versión posprint
Loading...
Thumbnail Image
Name:
poster Assessment of Harmonic Distortion.pdf
Size:
504.4 KB
Format:
Adobe Portable Document Format
Description:
Póster