Design and implementation of a smart sensor for respiratory rate monitoring
| dc.contributor.author | Aponte Luis, Juan | |
| dc.contributor.author | Roa Romero, Laura M. | |
| dc.contributor.author | Gómez Galán, Juan Antonio | |
| dc.contributor.author | Naranjo Hernández, David | |
| dc.contributor.author | Estudillo Valderrama, Miguel Ángel | |
| dc.contributor.author | Barbarov Rostán, Gerardo | |
| dc.contributor.author | Rubia Marcos, Carlos Rodrigo | |
| dc.date.accessioned | 2017-04-06T12:27:37Z | |
| dc.date.available | 2017-04-06T12:27:37Z | |
| dc.date.issued | 2014 | |
| dc.description.abstract | This work presents the design, development and implementation of a smart sensor to monitor the respiratory rate. This sensor is aimed at overcoming the drawbacks of other systems currently available in market, namely, devices that are costly, uncomfortable, difficult-to-install, provide low detection sensitivity, and little-to-null patient-to-patient calibration. The device is based on capacitive sensing by means of an LC oscillator. Experimental results show that the sensor meets the necessary requirements, making feasible the proposed monitoring system with the technology used. | en_US |
| dc.description.department | Ingeniería Electrónica, de Sistemas Informáticos y Automática | |
| dc.description.sponsorship | This work has been supported by the Spanish Ministry of Science and Innovation, and FEDER funds under grant FPA2010-22131-C02-02, and by the Andalussian Innovation, Science and Enterprise Council, under grants P08-TIC-04069 and P10-TIC-6311. | |
| dc.identifier.citation | Aponte Luis, J., Roa Romero, L.M., Gómez Galán, J.A., Naranjo Hernández, D., Estudillo Valderrama,M.A., Barbarov Rostán, G., Rubia Marcos, C.: "Design and implementation of a smart sensor for respiratory rate monitoring". Sensors. Vol. 14, págs. 3019-3032, (2014). DOI: 10.3390/s140203019 | en_US |
| dc.identifier.doi | 10.3390/s140203019 | |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.uri | http://hdl.handle.net/10272/13561 | |
| dc.language.iso | eng | en_US |
| dc.publisher | MDPI | en_US |
| dc.relation.projectID | info:eu-repo/grantAgreement/Andalussian Innovation, Science and Enterprise Council [P08-TIC-04069, P10-TIC-6311]info:eu-repo/grantAgreement/FEDER [FPA2010-22131-C02-02] | |
| dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
| dc.rights.accessRights | open access | en_US |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
| dc.subject.other | Capacitive technology | en_US |
| dc.subject.other | Respiratory rate monitoring | en_US |
| dc.subject.other | Smart sensor | en_US |
| dc.title | Design and implementation of a smart sensor for respiratory rate monitoring | en_US |
| dc.type | journal article | en_US |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 0dd63bee-e1d6-4920-bfee-925552b452d3 | |
| relation.isAuthorOfPublication | 81eec217-1178-49c7-b76a-5e16451143ec | |
| relation.isAuthorOfPublication.latestForDiscovery | 0dd63bee-e1d6-4920-bfee-925552b452d3 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Design and Implementation.pdf
- Size:
- 534.14 KB
- Format:
- Adobe Portable Document Format
- Description:
- versión editor


