Unbalance and harmonic distortion assessment in an experimental distribution network

dc.contributor.authorDelgado Martín, Aránzazu
dc.contributor.authorSánchez Herrera, María Reyes
dc.contributor.authorRodríguez Vázquez, Jesús
dc.contributor.authorCrolla, Paul
dc.contributor.authorBurt, Graeme M.
dc.date.accessioned2024-01-30T11:54:37Z
dc.date.available2024-01-30T11:54:37Z
dc.date.issued2015
dc.description.abstractThe identification of voltage and current harmonic distortion and voltage unbalance sources is one of the main problems in electric distribution systems. In order to overcome it, in this paper the use of two novel indices is proposed. On the one hand, the Load Characterization Index (LCI) is suggested to calculate the harmonic distortion introduced by the load. This index identifies linear and non-linear loads in the power systems. On the other hand, the Unbalance Current Ratio (UCR) is suggested to assign the responsibility for system unbalance to load and source sides. Both indices can be calculated only from the measurement of the current at the input of the load and the voltage at the Point of Common Connection (PCC). The main objective of this paper is to test the performance of these two indices on an experimental three-phase electrical network. In order to do that, several experimental tests have been considered.es_ES
dc.description.departmentIngeniería Eléctrica y Térmica, de Diseño y Proyectos
dc.description.sponsorshipThis work was supported in part by DERri Programme and the European Commission as well as this work was also supported in part by the Ministerio de Educación under the FPU grant.es_ES
dc.identifier.citationDelgado-Martin, A., Herrera, R. S., Rodríguez-Vázquez, J., Crolla, P., & Burt, G. M. (2015). Unbalance and harmonic distortion assessment in an experimental distribution network. In Electric Power Systems Research (Vol. 127, pp. 271–279). Elsevier BV. https://doi.org/10.1016/j.epsr.2015.06.005es_ES
dc.identifier.doi10.1016/j.epsr.2015.06.005
dc.identifier.issn0378-7796
dc.identifier.issn1873-2046 (electrónico)
dc.identifier.urihttps://hdl.handle.net/10272/23020
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.epsr.2015.06.005es_ES
dc.rights.accessRightsopen accesses_ES
dc.subject.otherHarmonic distortion sourcees_ES
dc.subject.otherDistribution networkses_ES
dc.subject.otherNon-linear loadses_ES
dc.subject.otherUnbalancees_ES
dc.subject.unesco33 Ciencias Tecnológicases_ES
dc.titleUnbalance and harmonic distortion assessment in an experimental distribution networkes_ES
dc.typejournal articlees_ES
dc.type.hasVersionAM
dspace.entity.typePublication
relation.isAuthorOfPublicationc4a2d3a9-7add-4e1d-8b0b-c7773b402593
relation.isAuthorOfPublicationb62dcfe6-e843-4ed6-b672-071e1301977b
relation.isAuthorOfPublication02d611ee-2cb7-4d45-946d-a2fcf389107c
relation.isAuthorOfPublication.latestForDiscoveryc4a2d3a9-7add-4e1d-8b0b-c7773b402593

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
EPSR_4354.pdf
Size:
673.76 KB
Format:
Adobe Portable Document Format
Description:
Versión postprint

Collections