uhuMEBr: Energy Refurbishment of Existing Buildings in Subtropical Climates to Become Minimum Energy Buildings
| dc.contributor.author | Gómez Melgar, Sergio Jesús | |
| dc.contributor.author | Martínez Bohórquez, Miguel Ángel | |
| dc.contributor.author | Andújar Márquez, José Manuel | |
| dc.date.accessioned | 2020-05-12T11:24:18Z | |
| dc.date.available | 2020-05-12T11:24:18Z | |
| dc.date.issued | 2020-03 | |
| dc.description.abstract | Today, most countries in the world have mandatory regulations, more or less strict, regarding energy effciency in buildings. However, a large percentage of the buildings already built were constructed under lax or non-existing regulations in this regard. Therefore, many countries are facing the energy refurbishment of their existing buildings to reduce their carbon footprint. Depending on ambient weather conditions where a building settles, its operation with respect to the achievement of maximum energy effciency should usually be different. This happens in subtropical climates when, during the year and depending on the season, the building needs to conserve heat, evacuate it or even make an exchange with the outside to take advantage of favorable environmental conditions. This paper presents a complete methodology for conducting building energy effciency refurbishments in subtropical climates in order to convert them into minimum energy buildings. The proposed methodology is illustrated by a case study in a dwelling that includes all the stages, from the analysis of the existing dwelling to the refurbishment works, showing the final results and the subsequent dwelling operation. | es_ES |
| dc.description.department | Ingeniería Electrónica, de Sistemas Informáticos y Automática | |
| dc.identifier.citation | Gómez Melgar, S., Martínez Bohórquez, M. Á., Andújar Márquez, J. M. (2020). uhuMEBr: Energy Refurbishment of Existing Buildings in Subtropical Climates to Become Minimum Energy Buildings. Energies, 13(5), 1204. DOI: https://doi.org/10.3390/en13051204 | es_ES |
| dc.identifier.doi | 10.3390/en13051204 | |
| dc.identifier.issn | 1996-1073 | |
| dc.identifier.uri | http://hdl.handle.net/10272/17914 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | MDPI | es_ES |
| dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
| dc.rights.accessRights | open access | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
| dc.subject.other | Energy effiency | es_ES |
| dc.subject.other | Subtropical climate building | es_ES |
| dc.subject.other | Minimum-Energy Building | es_ES |
| dc.subject.other | MEB | es_ES |
| dc.subject.other | Building refurbishment | es_ES |
| dc.subject.other | Building rehabilitation | es_ES |
| dc.subject.other | Building renovation | es_ES |
| dc.subject.other | Envelope airtightness | es_ES |
| dc.subject.other | Envelope thermography | es_ES |
| dc.subject.other | Envelope transmittance | es_ES |
| dc.title | uhuMEBr: Energy Refurbishment of Existing Buildings in Subtropical Climates to Become Minimum Energy Buildings | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | VoR | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 606e7d4d-2c00-4885-8b38-153c9e30b836 | |
| relation.isAuthorOfPublication | 29aafa26-f66e-43ba-9c51-25ef75bf72aa | |
| relation.isAuthorOfPublication | ae5faff8-3c02-43cd-a650-2e754e1995fa | |
| relation.isAuthorOfPublication.latestForDiscovery | 606e7d4d-2c00-4885-8b38-153c9e30b836 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- uhuMEBr.pdf
- Size:
- 10.53 MB
- Format:
- Adobe Portable Document Format
- Description:
- PDF versión editor